VSCOM NetCAN Plus 120 WLAN - Converter Ethernet/WLAN to CAN Bus
- — אחריות: שנה אחריות
- — החזרה והחלפה עד 30 יום
- — המחיר הטוב ביותר
The NetCAN Plus series consists of smart Ethernet to CAN-Bus gateways, making the integration of CAN-Busses into existing Ethernet network topologies possible. Higher layer protocols, such as CANopen, can be assembled using the available development tools for complex automation control applications. Properties such as low power consumption (2W typical), an extended temperature range (−20C - +65°C), a wide power supply (9 - 54V DC) and a solid MTBF (17 Years at 45°C) make it an ideal system for industrial automation. The Wireless LAN also supports connections from PC to the NetCAN Plus without an existing Wifi network.
Operation Modes
NetCAN Plus series supports three operating modes: TCP Raw Server, CAN Bridge and Driver Mode. With the TCP Raw Server the communication is handled directly via IP address and port number. The CAN Bridge connects two CAN-Busses over an Ethernet/WLAN/VPN tunnel using two NetCAN Plus devices. The Driver Mode requires the installation of a virtual com-port driver, which makes the network fully transparent to the application.
Usage Options
NetCAN Plus provides various software tools to interface each level of the user applications:
- The ASCII conversion protocol is handy in developing and testing any CAN-BUS configuration. Users simply connect directly via Telnet, and have a simple way to talk to the CAN controller. The device can also be used to manually transmit and receive CAN frames.
- Applications programmed by users should use the VScan API library (DLL), which handles the communication and ASCII conversion for the CAN frames in a transparent manner. In their applications, programmers have to handle only the CAN frames and status information, without taking care of the ASCII conversion. The VScan API is supported in C/C++, C#, VB.NET, Delphi and LabVIEW. Under Linux SocketCAN can be used as alternative to VScan API. All VScom CAN devices support the standard Serial Line CAN (slcan) driver.
- The NetCAN Plus series also supports CANFestival, an Open Source CANopen Framework. CANopen is a CAN-based higher layer protocol that is used in various application fields to unburden the developer from dealing with CAN-specific details. CANopen provides standardised communication objects for real-time data, configuration data as well as network management data.
- The SAE J1939 protocol, resting upon the CAN hardware layer, is commonly used in the commercial vehicle area. A lot of other modern protocols are based on it, like NME200, ISOBUS, MilCAN or FMS. Vscom’s J1939 API also includes support for the so called Transport Protocol, which will bypass the limit of 8 data bytes per message. It's available on J1939-enabled devices. Supports Windows, Linux, .NET
Secure Remote Access
For the NetCAN Plus series there is a software option using the viaVPN Cloud system, which can be remotely accessed and monitored over the Internet. viaVPN provides secure and strongly encrypted access, without the need for any reconfiguration of existing firewalls. In case a customer's firmware/application is accessible via Ethernet or Wifi — as for example via a web interface or Telnet/SSH connection — viaVPN extends the access over internet by a protected VPN tunnel. If the CAN-Bus port is not occupied by local access, also remote operation over Internet is possible.
Features
- Connects CAN-Bus via LAN to PC
- Supports CAN 2.0A / 2.0B at 1MBit/s
- LAN 100/10 Ethernet auto-detect
- WLAN 802.11b/g/n (WLAN model only)
- CANopen supported by CANFestival
- SAE J1939 protocol supported by Vscom’s J1939 API
- Bridge mode to tunnel 2 CAN-Busses
- Easy-to-use DLL Library for CAN bus access
- Remote Frame support, Listen only mode
- OS supported: Windows, Linux, Windows CE
- Development: C/C++, C#, VB.NET, LabVIEW, Delphi
- Secure Remote Access by viaVPN Cloud (optional)
- Supports Bosch Busmaster Debugging
- 16kV ESD surge protected
- Wide range power supply 9 - 54V
- Extended temperature −20C - +65°C
- DIN-Rail mountable (optional)
Specifications
Speed/Type | 100Mbps/10Mbps Auto-detecting |
Connector | RJ45 (8P8C) 8 pin |
LEDs | Power, WLAN, Ready, Ethernet Link / Speed |
No. of Ports/Type | 1 × CAN Bus |
Connector | DB9 male |
Protection | 16kV ESD surge protection |
Signals | CAN_H, CAN_L, CAN_GND |
Speed | CAN 2.0A / 2.0B 1Mbit/s |
LED | CAN-Data, CAN-Error |
TCP Raw Server | Raw Data transfer over TCP/IP. Accepts multiple incoming connections. |
CAN Bridge | CAN networks are connected via TCP/IP (WLAN or Ethernet). A client connects to a Server, CAN frames received on one network are repeated on the other network. |
Virtual Com Mode | Driver for virtual COM port available for Windows 2000, XP up to Windows 10 Windows Server 2000 up to 2008 R2 |
VSCAN API | Unified API for control all VScom CAN-Adapters. Supported OS: Windows, CE, Linux (x86, x86-64, ARM) targets. Supported Dev.Env: C/C++, C#, VB.NET, Delphi and LabVIEW. |
Linux OS | Supports SocketCAN (slcan driver) since kernel 2.6.38+ Also see this FAQ |
CANopen | Open source CANfestival framework fully implements CANopen functionality. |
SAE J1939 | Automotive protocol suite supported by Vscom’s J1939 API. Supports NME200, ISOBUS, MilCAN and FMS protocols for Windows, Linux and .NET |
Monitoring Tools | Bosch BUSMASTER v3.2.0 and above |
Data Coding | ASCII format |
CAN Modes | Standard ModeNormal operation on CAN busListen ModePassive receive of CAN Frames, neither ACK bits nor Error Frames are sentSelf Reception (Echo Mode)For testing: Transmitted Frames are also received by the adapter |
UPnP | With Network discovery enabled NetCom Plus servers announce their presence via UPnP making their IP visible. |
Configuration | NetCom Manager to find and configure NetCANs in network Driver Panels, WEB Browser, Serial Console, Telnet, SNMP |
Firmware Update | via WEB Browser |
Firewall | Virtual-COM mode works through firewalls |
Password Protection | for all available configuration options e.g. via WEB-Browser |
Secure Server | create openVPN™ tunnels, for encrypted transmission of all serial and configuration data using high security SSL/TLS standards. |
Connect via Internet | viaVPN technology provides easy and secure access to remotely installed NetCom Plus servers for their configuration or for connecting their virtual COM ports through Internet. With the viaVPN option the NetCom Plus servers are no more limited to only work inside of a local network. |
Security | All communications use openVPN-tunnels encrypted by SSL/TLS and AES-256 standards. |
Firewall friendly | No Reconfiguration of firewalls is required for viaVPN remote access. |
Standards | 2.4GHz Radio, supports IEEE Std. 802.11b/g/n |
WLAN Modes | Access Point (AP) or Client (Station) |
TX Power | 802.11b:Typ. 15.5dBm ±1.5 dBm @ 1Mbps (DSSS)Typ. 15.5dBm ±1.5 dBm @ 11Mbps (OFDM)802.11g:Typ. 15.6dBm ±1.5 dBm @ 6Mbps (CCK)Typ. 13.5dBm ±1.5 dBm @ 54Mbps (OFDM)802.11n:Typ. 13.4dBm ±1.5 dBm @ 6.5Mbps (OFDM)Typ. 13.3dBm ±1.5 dBm @ 150 Mbps(OFDM) |
RX Sensitivity | 802.11b:-95.6dBm @ 1Mbps, -88dBm @ 11Mbps802.11g:-91.3dBm @ 6Mbps, -74.2dBm @ 54 Mbps802.11n:-88.8dBm @ 6.5Mbps (20 MHz), -72dBm @ 72.2Mbps (20 MHz) |
Transmission Rate | 802.11b: 11Mbps 802.11g: 6 to 54Mbps 802.11n: 6.5 to 150Mbps |
Transmission Distance | Up to 100m in open areas |
Wireless security | WEP WPA WPA2 WPA2-Enterprise (IEEE 802.1X/RADIUS) |
Antenna Connector | RP (Reverse-Polarity) SMA |
Input Voltage | 9 - 54V DC |
Power Consumption | 0.25A @ 12V, 2.7W max |
Connector | 3-pin Terminal Block |
Case | 0.8mm sheet metal |
Weight | w/o box 0.25kg; w/h box 0.40kg |
Dimensions | 115×73×25 mm³ (W×L×H) |
Packaged | 150×107×48 mm³ |
Mounting | DIN-Rail (optional) Wall mount (optional) |
Operating Temp | −20°C - 65°C |
Storage Temp | −20°C – 85°C |
Ambient Humidity | 5-95% non condensing |
Declarations | CE, FCC |
EMI | EN 55022 Class B EN 61000-3-2: Limits of harmonic current emissions EN 61000-3-3: Limitation of voltage changes 47 CFR FCC Part 15 Subpart B |
EMS (EN 55024) | EN 61000-4-3: Radiated RFI EN 61000-4-4: Electrical Fast Transient EN 61000-4-5: Surge EN 61000-4-6: Induced RFI EN 61000-4-8: Power Frequency Magnetic Field EN 61000-4-11: Power supply dips |
ESD | IEC 61000-4-2 4kV contact 8kV air for CAN Bus Port USB Ethernet DC Power connector |
MTBF | 42.4 Years @ 25°C 13.7 Years @ 45°C |
MTBF WLAN model | 34.4 Years @ 25°C 12.7 Years @ 45°C |
Standard | Telcordia (Bellcore) Standard; RelCalc. 5.0 BELL-7 |
Packing list | NetCAN Plus CAN Bus Gateway Terminal block for Power Supply Reverse SMA Antenna (WLAN model only) |